Nombre De Pièces: | 1pcs |
Prix: | Négociable |
Emballage Standard: | Original packing |
Période De Livraison: | On request |
Méthode De Paiement: | T/T |
Capacité D'approvisionnement: | 50pcs/month |
7F2C25-AAGCCAACAAAD2SKA1+AK Proline Prowirl F 200 vortex flowmeter
Volume flow (liquid): ±0.75 %
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%
Liquid: 0.2 to 2100 m³/h (0.15 to 1520 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
PN 100, Class 600, 20K
Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
Suitable for a wide range of applications; optimized for steam applications
Device properties
Wet steam capabilities for DN 25 to 300 (1 to 12")
Flexible positioning of pressure cell
Industrial siphon design for pressure measurement
Display module with data transfer function
Robust dual-compartment housing
Plant safety: worldwide approvals (SIL, Haz. area)
CPF81D-7LH11 | 8 | E+H |
FMI51-A1BTDJB1A1A L=1800MM | 1 | E+H |
CPS12D-7PA2G | 1 | E+H |
COS51D-AS800 | 1 | E+H |
CPS72-0PT2GSA | 2 | E+H |
CPS31-1AC2GSA | 5 | E+H |
FTL31-AA4U3BAWBJ | 1 | E+H |
PTP33B-AA7M1PGB3CJ+LBLD | 2 | E+H |
CLS15-B1M2A | 5 | E+H |
FMU40-ARH1A2 | 4 | E+H |
V18345.10.1.0.2.2.1.00.1 | 50 | ABB |
V18345.10.1.0.5.2.1.00.1 | 130 | ABB |
V18345-1010121001 | 35 | ABB |
PMP23-AA1U2MBWSJ+QJ | 1 | E+H |
PMP23-AA1U2MBWSJ+QJ | 1 | E+H |
PMC11-1C58/142 | 1 | E+H |
FMU41-ARD2A2 | 3 | E+H |
FTL50-AGQ6AA2G5A | 2 | E+H |
CUS52D-AA1HA2 | 6 | E+H |
CUA250-A | 2 | E+H |
CPS11D-7BT21 | 1 | E+H |
CPS12D-7NA21 | 1 | E+H |
CLS21D-C1E1 | 5 | E+H |
Nombre De Pièces: | 1pcs |
Prix: | Négociable |
Emballage Standard: | Original packing |
Période De Livraison: | On request |
Méthode De Paiement: | T/T |
Capacité D'approvisionnement: | 50pcs/month |
7F2C25-AAGCCAACAAAD2SKA1+AK Proline Prowirl F 200 vortex flowmeter
Volume flow (liquid): ±0.75 %
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85%
Liquid: 0.2 to 2100 m³/h (0.15 to 1520 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 1.5 to 28000 m³/h (0.9 to 16600 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
PN 100, Class 600, 20K
Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
Suitable for a wide range of applications; optimized for steam applications
Device properties
Wet steam capabilities for DN 25 to 300 (1 to 12")
Flexible positioning of pressure cell
Industrial siphon design for pressure measurement
Display module with data transfer function
Robust dual-compartment housing
Plant safety: worldwide approvals (SIL, Haz. area)
CPF81D-7LH11 | 8 | E+H |
FMI51-A1BTDJB1A1A L=1800MM | 1 | E+H |
CPS12D-7PA2G | 1 | E+H |
COS51D-AS800 | 1 | E+H |
CPS72-0PT2GSA | 2 | E+H |
CPS31-1AC2GSA | 5 | E+H |
FTL31-AA4U3BAWBJ | 1 | E+H |
PTP33B-AA7M1PGB3CJ+LBLD | 2 | E+H |
CLS15-B1M2A | 5 | E+H |
FMU40-ARH1A2 | 4 | E+H |
V18345.10.1.0.2.2.1.00.1 | 50 | ABB |
V18345.10.1.0.5.2.1.00.1 | 130 | ABB |
V18345-1010121001 | 35 | ABB |
PMP23-AA1U2MBWSJ+QJ | 1 | E+H |
PMP23-AA1U2MBWSJ+QJ | 1 | E+H |
PMC11-1C58/142 | 1 | E+H |
FMU41-ARD2A2 | 3 | E+H |
FTL50-AGQ6AA2G5A | 2 | E+H |
CUS52D-AA1HA2 | 6 | E+H |
CUA250-A | 2 | E+H |
CPS11D-7BT21 | 1 | E+H |
CPS12D-7NA21 | 1 | E+H |
CLS21D-C1E1 | 5 | E+H |